Touchstone™
Telephony Modem TM502G
Visit www.arrisi.com for more information 060510_Touchstone_Telephony_Modem_TM502G.doc
Specifications
Ordering Information
Physical: Operating Temperature °F (°C) .........................41 to 104 (5 to 40)
Operating Relative Humidity (Min-Max).. 5-85%(Non condensing)
Storage Temperature °F (°C)....................... -40 to 158 (-40 to 70)
Color ................................................................................Dark gray
Dimensions (H x W x D) in. (cm)8.6 x 2.1 x 7.1 (21.8 x 5.3 x 18.0) -
Weight lbs (kg).......... ………………No battery included: 1.2 (0.54)
Battery: 5 Hour Back-up Option (-4)
Backup Capacity........................................... Lithium-ion 2.2 Ah
Battery Dimensions in. (cm) ...1.2 x 1.85 x 3.1 (3.0 x 4.7 x 7.9)
Weight lbs (kg)............................................................1.5 (0.66)
Battery: 10 Hour Back-up Option (-8)
Backup Capacity........................................... Lithium-ion 4.4 Ah
Battery Dimensions in. (cm)..1.2 x 1.85 x 5.7 (3.0 x 4.7 x 14.5)
Weight lbs (kg)..........................................................: 1.7 (0.77)
Battery Storage Temperature °F (°C) ............ -4 to 140 (-20 to 60)
Note: Storage above 77°F (25°C) will significantly reduce life
of the battery and not recommended.
Telemetry. AC Fail, Battery Low, Battery Missing, Replace Battery
Diagnostic LEDsPower, DS, US, Online, Link, Telephone 1, Telep
h
Interfaces: RF Interface .........................................External ‘F’ type connector
Data Interfaces (bridged)..........................10/100 Base-T Ethernet
........................... (RJ-45 connector), USB 1.1 Series B connector
Telephony Interface .... 2 lines; RJ-14 (“Line 1/2"), RJ-11 (“Line 2”)
Input Power (nominal ) .............................. 100-240 VAC 50/60 Hz
Telephony:
Supervisory Voltage.............................................. 48 V dc nominal
Maximum Loop Length to CPE............................1500 ft (457M) of
....................................................................26 AWG (0.4 mm) wire
Ringing Load Capacity...............................10 REN total; 5 per line
Provisionable High Loop Current Mode....................................Yes
Telcordia™ GR 1089 (Lightning and Power Surge) Tested ..... Yes
Programmable Interface for
Worldwide Applications.............................................................Yes
............................................. (supports multiple country templates)
RF
Downstream:
Frequency Range (MHz) .....................................................88-860
Modulation (QAM)............................................................ 64 or 256
Data Rate (Mbps) ......................................................... up to 42.88
RF Input Sensitivity Level (dBmV)....................................-15 to 15
Bandwidth .............................................................................6 MHz
RF Upstream: Frequency Range (MHz) .........................................................5-42
Modulation ..............................................QPSK, 8 QAM, 16 QAM,
...............................32 QAM, 64 QAM & 128 QAM (S-CDMA only)
Data Rate (Mbps) (Max.) ............................................. up to 30.72
RF Output Level (dBmV) .................................................. A-TDMA
+8 to 54 dBmV (32 QAM, 64 QAM)
+8 to 55dBmV (8 QAM, 16 QAM)
+8 to 58 dBmV (QPSK)
S-CDMA
+8 to +53 dBmV (all modulations)
Automatic Level Adjust .............................................................Yes
Gain Control Range (dB) ............................................................ 50
Frequency Stability (kHz)............................................................ ±5
Output Impedance (Ohms) ......................................................... 75
Standards: Codec: G.711, 64 kbps,  and A-law encoded speech
Enhanced codec support (G.726, G.728, G.729E)
T.38 Fax Relay
DOCSIS 2.0 based
PacketCable 1.0 & 1.5 based
RFC3261 SIP: Session Initiation Protocol
UL® 60950, FCC Part 15 Class B, CE
WHQL and USB-IF
Touchstone TM502G/NA-0 DOCSIS 2.0 / PacketCable
1.0/1.5 Complaint E-MTA Integrated 100-240 VAC, 50/60 HZ
Power supply w/ 12 foot power cord with NEMA 1-15 pass-
through power plug Includes Quick Install Guide, Ethernet
Cable, USB Cable, and CD-ROM with users guide and USB
drivers NO battery included ....................................717947
Touchstone TM502G/NA-4 DOCSIS 2.0 / PacketCable
1.0/1.5 Complaint E-MTA Includes 1, 2-cell, Li-Ion Battery
Pack for up to 5 hours of battery back-up Integrated 100-240
VAC, 50/60 HZ Power supply w/ 12 foot power cord with
NEMA 1-15 pass-through power plug Includes Quick Install
Guide, Ethernet Cable, USB Cable, and CD-ROM with users
guide and USB drivers ..............................................717948
Touchstone TM502G/NA-8 DOCSIS 2.0 / PacketCable
1.0/1.5 Complaint E-MTA Includes 1, 4-cell, Li-Ion Battery
Pack for up to 10 hours of battery back-up Integrated 100-
240 VAC, 50/60 HZ Power supply w/ 12 foot power cord with
NEMA 1-15 pass-through power plug Includes Quick Install
Guide, Ethernet Cable, USB Cable, and CD-ROM with users
guide and USB drivers ..............................................718001
Touchstone TM502G/CE-0 DOCSIS 2.0 / PacketCable
1.0/1.5 Complaint E-MTA Includes 1, 2-cell, Li-Ion Battery
Pack for up to 5 hours of battery back-up Integrated 100-240
VAC, 50/60 HZ Power supply w/ 12 foot power cord with
CEE 7/16 “Euro” Power Plug pass-through power plug
Includes Quick Install Guide, Ethernet Cable, USB Cable,
and CD-ROM with users guide and USB drivers NO battery
included....................................................................717949
Touchstone TM502G/CE-4 DOCSIS 2.0 / PacketCable
1.0/1.5 Complaint E-MTA Includes 1, 2-cell, Li-Ion Battery
Pack for up to 5 hours of battery back-up Integrated 100-240
VAC, 50/60 HZ Power supply w/ 12 foot power cord with
CEE 7/16 “Euro” Power Plug Includes Quick Install Guide,
Ethernet Cable, USB Cable, and CD-ROM with users guide
and USB drivers ........................................................717950
Touchstone TM502G/CE-8 DOCSIS 2.0 / PacketCable
1.0/1.5 Complaint E-MTA Includes 1, 4-cell, Li-Ion Battery
Pack for up to 10 hours of battery back-up Integrated 100-
240 VAC, 50/60 HZ Power supply w/ 12 foot power cord with
CEE 7/16 “Euro” Power Plug Includes Quick Install Guide,
Ethernet Cable, USB Cable, and CD-ROM with users guide
and USB drivers ........................................................718046
One 2-Cell, 2.2 Ah,
Li-Ion Battery Pack for TM502G................................718003
Kit of 60, 2-Cell, 2.2 Ah,
Li-Ion Battery Packs for TM502G..............................718004
One 4-Cell, 4.4 Ah,
Li-Ion Battery Pack for TM502G................................718005
Kit of 30, 4-Cell, 4.4 Ah,
Li-Ion Battery Packs for TM502G..............................718006
Battery back-up times are typical and can be influenced by the age of the battery, the charging state, storage conditions and operating temperature as well as factors such as
data activity and length of active telephone calls. The capabilities, system requirements and/or compatibility with third-party products described herein are subject to change
without notice. The capabilities, system requirements and/or compatibility with third-party products described herein are subject to change without notice. ARRIS, the ARRIS
logo, Cadant®, D5™, Touchstone®, Cornerstone®, Keystone™, C4®, C3™, CXM™ Regal®, MONARCH®, Digicon® and TeleWire Supply® are all trademarks of ARRIS
International, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and the names of their products. ARRIS
disclaims proprietary interest in the marks and names of others. © Copyright 2006 ARRIS International, Inc. All rights reserved. Reproduction in any manner whatsoever without
the express written permission of ARRIS International, Inc., is strictly forbidden. For more information, contact ARRIS.
10 May 2006